SIMPLEX 4100ES FIRE ALARM CONTROL PANEL
4100ES addressable fire alarm control panels support up to 2,500 points, fire alarm and emergency voice communication, self-testing notification appliances and IP based networking. With scalable architecture and future-proof design, 4100ES panels are ideal for medium to large facilities and multi-building campus style networks. All Simplex addressable panels rely on TrueAlarm addressable detectors.
PDF Download Here:
LCD AND LED ANNUNCIATOR
- LCD readout provides: Two lines of 40 characters each; wide viewing angle; LED backlighting.
- Control switches and status LEDs – Alarm, Priority 2, Supervisory, or Trouble acknowledge (keyswitch access controlled), alarm silence, System reset
- Programmable control switches with yellow
LEDs and provisions for custom labeling - Tone-alert sounder provides local audible indication
- Lamp and LCD are functionally tested each time the
keyswitch is turned on
PDF Download Here:
SIMPLEX 4098-9714 AUTOMATIC FIRE SMOKE DETECTOR
The Simplex 4098-9714 is an analog and addressable, replacement, photoelectric smoke detector head. The Simplex 4098-9714 sensor head is designed to provide 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow for the Simplex 4098-9714.
PDF Download Here:
SIMPLEX 4098-9733 Heat Detector
TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise
temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm
control panel.
TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C).
PDF Download Here:
SIMPLEX 4098-9754 Multi Detector
TrueAlarm multi-sensor model 4098-9754 combine the established performances of a TrueAlarm photoelectric smoke sensor with a fast-acting and accurate TrueAlarm thermal sensor to provide both features in a single sensor/base assembly. Digital Communication of Analog Sensing. Analog information from each sensor is digitally communicated to the control panel where it is analyzed.
PDF Download Here:
ADDRESSABLE MANUAL PULL STATIONS
- Multiple operation types – Single action; Double action, Breakglass operation; Double Action, Push operation; Single action NO GRIP operation. Operation complies with ADA requirements.
- Individually addressable manual fire alarm stations – Power and data supplied via IDNet or MAPNET II addressable communications using a single wire pair. Compatible with Simplex fire alarm control panels equipped with either IDNet or MAPNET II communications.
PDF Download Here:
TrueAlert Non-Addressable Horn
TrueAlert non-addressable horn model 4901-9820 is an audible notification appliance with a loud and penetrating, harmonically rich sound that can be controlled either directly from a standard NAC (freerun operation mode) or by the SmartSync two-wire operation mode. Standard (free-run) operation mode. In the free-run mode, a positive voltage from the controlling NAC will activate the horn according to the desired output of continuous or coded output per the controlling NAC’s capabilities.
PDF Download Here:
TrueAlert Multi-Candela Notification Appliances
Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated.
PDF Download Here:
TrueAlarm Duct Detectors
- features:
- On-board TrueAlarm sensitivity drift compensation and dirt accumulation tracking
- Multi-function status LED indicator
- Magnetic test that initiates an alarm and provides detailed diagnostic information
- Clear cover allowing visual inspection
- Test ports provide functional smoke testing access with cover in place
- UL listed to Standard 268A
PDF Download Here:
SIMPLEX MONITOR/INPUT MODULE
Individual addressable modules (IAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor.
PDF Download Here:
SIMPLEX CONTROL/OUTPUT MODULE
- Individual Addressable Relay Module (Relay IAM):
- IDNet addressable control for use with Simplex® fire alarm control panel models 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U
- A single addressable point provides control and status tracking of a Form “C” contact
- Low power latching relay design allows IDNet communications to supply both data and module power
PDF Download Here:
SIMPLEX SHORT CIRCUIT ISOLATOR
4090-9116 Addressable IDNet Communications Isolators provide IDNet communications isolation to improve installation convenience and increase system integrity. Isolation is automatically activated when an output short circuit is detected and isolation can also be selected manually from the control panel to assist with troubleshooting wiring problems. Operation. Isolators power-up in isolation mode and are directed to connect by the control panel. If the output wiring is acceptable, the isolator will connect to the rest of the circuit. If the output wiring is shorted, the isolator remains isolated
PDF Download Here:
Reflective Beam Smoke Detectors 50R/100R ~50RU/100RU
The Fireray® 50R/100R series of reflective infrared optical beam smoke detectors are comprised of a single unit incorporating an infrared Transmitter and Receiver. The signal is reflected by a prism and analysed for smoke presence. The system is designed to be mounted so that the beam will project between 0.3 and 0.6 metres below and parallel to the ceiling. Lateral detection may be up to 7.5 metres either side of the beam.
- Single Compact Housing
- Area coverage 50 metre or 100 metre model available
- 12-24 Vdc Operation
- Low current Consumption
- Robust Construction
- Conforms to: BS5839 Part 5 and EN54 part 12, UL and VdS
PDF Download Here:
Reflective Beam Smoke Detectors Auto-Aligning Fireray 5000
- Allows for 2 Detectors per System Controller
- Range 5 to 120 metres, configurable per set of Detectors
- Integral Laser Alignment in Receiver
- 2-wire Interface between Controller and Receiver
- Seperate Fire and Fault Relays per Detector
- Low Level Controller with LCD display
- Programmable Sensitivity and Fire/Fault delay
- Automatic Gain Control (AGC) for drift compensation
- First Fix concept for Transmitter, Receiver and Controller
- Multiple cable gland knockouts for ease of wiring
- Transmitter can be powered from Controller
- Patented Light Cancellation Technology (LCT) cancels unwanted light, including sunlight, sodium lamps and fluorescent lighting.
PDF Download Here:
End-to-End Infrared Optical Beam Smoke Detector FIRERAY 3000
- Allows for 2 Detectors per System Controller
- Each Detector configurable from 8m to 100m
- Separate Fire and Fault relays per Detector
- Integral LASER alignment
- Auto-Align Fast Automatic Beam Alignment
- Building Movement and Contamination Compensation
- Low Level System Controller
- Logs the 50 most recent events per detector
- Approved to EN54:12 and UL268
PDF Download Here: