FireNET® Series – DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL
STANDARD FEATURES
• UL 864 9th Edition Listed
• Seismic certified
• Digital Analog design using Hochiki’s advanced DCP protocol for fast and robust communication
• Up to 127 sensors & modules, plus 127 digital analog sounder bases, for a total of 254 points possible per loop
• Supports Class B (style 4) and Class A (style 6 or 7) SLC loops
• 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps each
• Programmable sensitivity levels per device & automatic day/night sensitivity modes
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD (320 char.)
• 2 loop (FN-2127 Series) or 4 loop (FN-4127 Series) versions (800 addresses/sub-addr. max.)
Download PDF Here:
FN-LCD-N-R – NETWORK ANNUNCIATOR, RED
STANDARD FEATURES
• UL 864 9th Edition Listed
• 320 character liquid crystal display (8 line x 40 character)
• RS485 slave bus for expansion – up to 32 FN-4127-IO boards
• 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
• 4 on board programmable Form C relays rated at 1 Amp at 30VDC (Fire, Supervisory, Trouble & Auxiliary)
• Same controls as the FireNET® fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)
• Dual RS485 ports for primary fire network
Download PDF Here:
FNP-LED – GRAPHIX LED DISPLAY
The FNP-LED system uses flexible, optic light guides to illuminate areas on a floor plan, laid over a high resolution grid.
STANDARD FEATURES
Available in red and gray
Available in 3 different size enclosures
LED’s come in 3 different colors: red, green, or yellow
FNP-LED can be easily upgraded onsite with minimal cost and effort
Download PDF Here:
ALN-V PHOTOELECTRIC SMOKE SENSOR
STANDARD FEATURES
* Low profile – only 2.00″ high, including base
* Simple and reliable device addressing
* Automatic compensation for sensor contamination
* Built-in fire test feature
* Uses the noise-immune Digital Communication
* Protocol (DCP), which utilizes interrupts for fast response to fires
* Two built-in power/alarm LEDs
* Programmable non-polling LEDs
* Non-directional smoke chamber
* Vandal resistant security locking feature
Download PDF Here:
ATJ-EA – FIXED TEMP/RATE OF RISE HEAT SENSOR
STANDARD FEATURES
• Low profile – only 2.00″ high, including base
• Simple and reliable device addressing method
• Uses the noise immune Digital Communication
• Protocol (DCP), which utilizes interrupts for fast response to fires
• Rate of rise temperature threshold = 15°F/min (determined by panel)
• Adjustable threshold temperature = 135°F – 190°F (determined by panel)
• UL maximum spacing of 70 feet
Download PDF Here:
ACD-V – MULTI-CRITERIA SENSOR – SMOKE, HEAT, CO DETECTOR
Watch the ACD-V Video Here
STANDARD FEATURES
• Low profile – only 2” high
• Simple and reliable device addressing
• Supports 16 operational modes
• Automatic compensation for sensor contamination
• Built-in fire test feature
• Uses the noise-immune Digital Communication Protocol (DCP),
which utilizes interrupts for fast response to fires
• Two built-in power/alarm LEDs
• Programmable non-polling LEDs
• Non-directional smoke chamber
• Vandal resistant security locking feature
• 10 years CO sensor life span*
• * Detectors must be replaced after 10 years from date of manufacturing
Download PDF Here:
DH-99AR – ADDRESSABLE DUCT SMOKE DETECTOR
STANDARD FEATURES
• Detects and limits the spread of smoke throughout building HVAC ducts
• Compatible with building automation and Fire Alarm Systems
• Installs quickly and easily
• No screen of filters to clean
• Rugged gray steel back box with clear cover
• Meets UL268A requirements
• Accessories – Remote LED alarm indication capability
Download PDF Here:
HSB-NSA-6 – 6″ SENSOR BASE
The YBN-NSA-4 and HSB-NSA-6 are designed specifically for use with the Hochiki NS Analog models AIEEA, ALG-V, ALK-V, ALK-D, ALN-V, ATG-EA, ATJ-EA and ACA-V.
STANDARD FEATURES
• UL & ULC Listed
• Designed for use with all NS analog sensors
• Available in 4 and 6 inch models
• Contains a security locking tab for tamper protection
Download PDF Here:
DCP-DIMM – DUAL INPUT MONITOR MODULE FOR 4″ BOX
STANDARD FEATURES
• UL 864 9th Edition Listed
• Fast, reliable contact monitoring utilizing the Hochiki DCP (Digital Communications Protocol)
• 127 devices can be used per DCP loop
• Bi-colored indicating LED provides module status
• Dual input contact monitor
• Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
• Operates on Class A or Class B SLC loop
• Accepts up to 14 AWG wire
Download PDF Here:
DCP-R2ML – DUAL RELAY MODULE
STANDARD FEATURES
• Provides two independently configurable Form C contacts per address
• Contacts are rated as follow:
R2ML: 2A @ 30 VDC / 0.5A @ 120 VAC
R2MH: 8A @ 30VDC / 4.8A @ 250 VAC
• Up to127 devices can be used on each SLC loop
• Visible Bi-colored LED is software controlled and can be programmed to blink red or green when polled. The LED can be latched on when activated
• Yellow LED indicates a short circuit condition (R2ML-I & R2MH-I only)
• Programming is highly flexible providing 16 priority states plus zoning capability
• Operates on Class A or Class B SLC loop
• UL 864 Listed
Download PDF Here:
DCP-CZM – CONVENTIONAL ZONE INPUT MODULE FOR
STANDARD FEATURES
• UL 864 9th Edition Listed
• Provides an address point for a zone of up to 25 conventional smoke detectors
• Blinks green when polled. Latched on red (controlled by panel) when activated
• Device address can be programmed with a handheld programmer. Device address- ranges from 1 to 127
• Compatible with Class B and Class A wiring
• Auxiliary power source provides power for the zone of detectors
• Compatible with conventional detectors, SLR, SIJ, SLK, SLV, DCD, DFE and SIH series
Download PDF Here:
DCP-SCI – SHORT CIRCUIT ISOLATOR
STANDARD FEATURES
• Can be placed at any location on SLC loop
• Checks the line for short circuit at power up. If the
line is normal, the relay will be returned on. If a
line short is detected, the relay remains open
• Indication of a single short circuit by a yellow LED
Download PDF Here:
DCP-AMS – ADDRESSABLE MANUAL PULL STATION
STANDARD FEATURES
• Addressable integrated design
• All metal construction
• Single and dual action models available
• Extremely easy to operate
• Bi-colored status LED indicates Standby and Alarm conditions
• Address is programmable in EEPROM
• Address can be programmed when installed
• Key lock or hex key lock models available
• Terminals accept up to 14AWG wire
• Surface mount back box available
Download PDF Here:
HES3-24WR – STROBE 24VDC, MULTI CANDELA, WALL MOUNT, RED
STANDARD FEATURES
- Nominal Voltage 12VDC and 24VDC
- 24VDC Units Have Field Selectable Candela Options of 15,30, 60, 75, and 110 Candela
- 12VDC Units Have Field Selectable Candela Options of 15,30, 60, and 75 Candela
- Unit Dimensions: 5″ high x 4.5″ wide x2.5″ Deep
- Synchronize Strobe with Hochiki Series Control Module(12VDC product must use the HAVSM Module)
- Prewire Entire System, then Install Signals
- Lower Installation and Operating Costs
Download PDF Here:
HEH24-WR – HORN 24VDC, WALL MOUNT, RED
The HE Series is a low profile strobe and horn/strobe combination that offers dependable audible and visual alarms and the lowest current available.
The HE Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC models offers tamperproof field selectable candela options of 15, 30, 60, and 75 candela.
The HE Series horn offers a continuous or synch able temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to change in the field by using switches. The HE Series has a minimal operation current and has a minimum flash rate of 1Hz regardless of input voltage.
Download PDF Here:
HCC24CR – HORN STROBE 24VDC, MULTI CANDELA, CEILING MOUNT, RED
STANDARD FEATURES
• Nominal Voltage 24 VDC
• Tamperproof Field Selectable candela options of 15, 30, 75, 95,115 & 150
• Unit Dimensions: 6″ x 2.6″
• Synchronize HC Series by using Hochiki America
Series Control Module
• Input Terminals support 12 to 18 AWG
• Switch Selection for High or Low dBA
• Switch Selection for 2400Hz or Mechanical Tone
• Switch Selection for Continuous or Temporal 3
• Tamperproof Re-entrant Grill
• Surface Mount with the HCSB (Hochiki Ceiling Surface Mount Box)
• Silence Horn While Strobes Remain Flashing
• Wide Voltage Range 16-33 VDC or FWR
• Faceplate Available in Red or Off-White
Download PDF Here:
PE-10SN – 10 AMP NAC EXTENDER
The Hochiki Notification Appliance Circuit Power Extender
STANDARD FEATURES
• (2) Trouble Relays
• (2) Class A or Class B Trigger Circuits
• (2) Class A or (4) Class B NAC Circuits
• QuadraSync Protocols Include: Gentex, System Sensor, Faraday, Wheelock and Amseco
• QuadraSync Offers the Capability to Have a Different Manufacturer Model Notification Devices on Each Circuit Through Dip Switch Configuration
• Supports 7 – 55AH Batteries
• Accommodates (2) 12VDC/12AH batteries
Download PDF Here:
FN-600ULX-R Power Supply
STANDARD FEATURES
• Cost Effective
• Filtered and Electronically Regulated Output
• AC Fail Supervision (Form C), Low Battery Supervision (Form C) and Battery Supervision (Form C)
• Built In Charger for Sealed Lead Acid or Gel Type Batteries
• Accommodates (2) 12VDC/7AH batteries
Download PDF Here:
Aspirating Smoke Detection Hochiki Firelink100
Features
Ultra small, low cost aspirating smoke detector for easy and discreet installation
High sensitivity provided by laser based forward light scatter for reliable early warning
Two sampling pipes up to 100 m (aggregate) in length (still air)
False alarms reduced by unique laser sensing technology – able to discriminate against dust
RS485 communications built in as standard for networking and remote communications
Download PDF Here:
EXPLOSION-PROOF – FLAMEPROOF, IR3 FLAME DETECTOR
STANDARD FEATURES
- Choices of Infra-Red Flame Detector are IR3, IR3-EX (Explosion Proof), IR3-IS (Intrinsically Safe)
- LPCB Listed and Certified to EN54-10 • Certified to II 2 G D
- Range of view up to 25m (82 ft.)
- Reduces false alarm by built-in combination filters and signal processing techniques
- Operates even if the lens is contaminated by a layer or oil, dust, water-vapor or ice
Download PDF Here: